…between an outlet and equipment. MSA Altair 4X and 5X Multi-Gas Detectors measure up to 5 and 6 (respectively) different gasses simultaneously and the run times and life expectancy exceed the industry average. * 48" cord* 110/220V AC and 12/24V DC* Compatible with Altair 4x or 5x multi-gas detector
Gas detector altair 5x for o2 lel co & h2s with pump charger probe and 10ft sampling line. Test work environments for 5 substances with the MSA 10116926 ALTAIR gas detector. Thick rubber housing prevents impact damage from falls up to 10 feet, and the nonslip profile ensures a secure grip. The…
…sampling system* System uses accurate direct reading detector tubes and a precision volumetric pump to ensure fast, easy-to-read, reliable, reproducible results* Each detector tube contains a reagent sensitive to a particular vapor or gas* The user simply breaks off both ends of the tube, inserts…
…sampling system* System uses accurate direct reading detector tubes and a precision volumetric pump to ensure fast, easy-to-read, reliable, reproducible results* Each detector tube contains a reagent sensitive to a particular vapor or gas* The user simply breaks off both ends of the tube, inserts…
Gas detector tube ammonia 5-100 ppm drager short term,8101941,10/box,5/6 . GAS DETECTOR TUBE AMMONIA 5-100 PPM DRAGER SHORT TERM,8101941,10/BOX,5/6 88046 12218 12336 53996 53997 551500 551504 76480 88280 88283 88535 49534 86019
Detector tube for co (carbon mono.) 5-50ppm 1ll 10/pkg for gastech monitor. * Accurately measure gases and vapors for over 600 applications* Fast, easy-to-read, reliable, reproducible results* Sold by the box 13138 69447 16389 18953 48110 48111 88467
Calibration gas model rp58 liter cylinder dot 39 60 ppm co, 1.45% ch4 15% o2 hazardous shipping. * MSA offers a complete line of calibration gas cylinders to calibrate all instruments* The gas mixture in calibration gas cylinders is certified to be prepared gravimetrically, using NIST traceable…
Calibration gas 34 liter 10048280 . * WEIGHT:1LB.1OZ. MATERIAL:ALUMINUM CONTENTS:34 LITERS PRESSURE:500 PSIG* Pentane Standard 1.45%* 15% Oxygen* 60 ppm CO* 20 ppm H2S* 44268* CALIBRATION GAS 34 LITER* 10048280 20719 44182 49774 53723 88570 88571 88572 88575 37014 37015 37016 44266 44337 46600 48957…
. * Drager Chip Measurement System (CMS) for gas and vapor spot measurements combines the advantages of chemistry and electronics to deliver accurate and reliable results* The system consists of two components, a substance-specific chip and an analyzer* Each chip contains 10 capillaries which are…